Aluminium windows and doors in Morocco: mandatory glass, coating and hardware standards
Aluminium windows, sliding doors and fixed frames in Morocco bring together many mandatory product standards. The old window standard NM 10.2.002 still applies, as do the standards for powder coatings on profiles (NM 03.2.232), basic glass (NM EN 572), toughened glass (NM EN 12150-1), laminated safety glass (NM ISO 12543), security glazing (NM EN 356), sealants (NM ISO 11600) and mechanical locks (NM EN 12209, in force since 18/03/2026). Air, water and wind performance classes are homologated standards that the CPS should name. The RTCM brings thermal requirements for glazing.
Scope
This page relates to external aluminium joinery: casement and sliding windows, sliding and pocket patio doors, fixed lights, and their glazing, hardware, seals and installation in the wall opening. Glazed curtain walls are covered on the façades page; interior timber doors on their own page.
Choices are made at design stage (performance, glazing, thermal break or not), confirmed by sample approval before ordering, and checked when the frames are installed during the renders stage. Final adjustment and acceptance happen at the inspection before handover.
Regulatory table
Reference, edition, status, the text that makes the rule mandatory and the verified source (standards catalogue 2026-10-25; NM statuses checked against the official list of the Ministry of Industry and Trade).
| Reference | Edition | Status | Text making it mandatory | Source | Note |
|---|---|---|---|---|---|
| NM 10.2.002 Fenêtres en bois ou en métal — spécifications | NM 10.2.002-1988 | mandatory | Décision/arrêté d'homologation n° 534-88 | MCINET list | Long-standing Moroccan specification for timber or metal windows, still of mandatory application. |
| NM 03.2.232 Peintures thermodurcissables en poudre Exigences et méthodes d’essais | NM 03.2.232-2020 | mandatory | Décision/arrêté d'homologation n° 2296-20 | MCINET list | Thermosetting powder coatings used on aluminium profiles; mandatory, approval decision No. 2296-20. |
| NM EN 572-1 Verre dans la construction — verre de silicate sodo-calcique | NM EN 572-1:2018 ; NM EN 572-3:2018 ; NM EN 572-6:2018 ; NM EN 572-7:2018 | mandatory | Décision/arrêté d'homologation n° 1357-18 | MCINET list | Basic soda-lime silicate glass products; mandatory. |
| NM EN 12150-1 Verre de sécurité trempé thermiquement | NM EN 12150-1:2018 | mandatory | Décision/arrêté d'homologation n° 1357-18 | MCINET list | Thermally toughened safety glass; mandatory for the toughened panes the architect specifies. |
| NM ISO 12543-2 / -3 Verre feuilleté et verre feuilleté de sécurité | NM ISO 12543-2:2018 ; NM ISO 12543-3:2018 | mandatory | Décision/arrêté d'homologation n° 1357-18 | MCINET list | Laminated and laminated safety glass, needed for low glazing and guarding; mandatory. |
| NM EN 356 Vitrage de sécurité — résistance à l'attaque manuelle | NM EN 356:2018 | mandatory | Décision/arrêté d'homologation n° 1357-18 | MCINET list | Security glazing against manual attack; mandatory where anti-intrusion glass is ordered. |
| NM ISO 11600 Produits pour joints Classification et exigences pour les mastics ; (IC 10.8.748) | NM ISO 11600:2018 | mandatory | Décision/arrêté d'homologation n° 3946-18, entrée en vigueur le 15/08/2025 | MCINET list | Sealants for the joint between frame and wall; mandatory since 15/08/2025. |
| NM EN 12209 Quincaillerie pour le bâtiment -Serrures-Serrures mécaniques et gâches-exigences et méthodes d’essai | NM EN 12209:2011 | mandatory | Décision/arrêté d'homologation n° 692-11, entrée en vigueur le 18/03/2026 | MCINET list | Mechanical locks and strike plates; mandatory, in force since 18/03/2026. |
| NM EN 12207 Fenêtres et portes — perméabilité à l'air — classification | 2018 | approved | — | IMANOR | Air permeability classes of windows and doors; homologated, to be stated in the CPS. |
| Décret n° 2-13-874 du 15/10/2014 Règlement général de construction fixant les règles de performance énergétique des constructions (RTCM) | 2014 | mandatory | The text itself (published in the Official Bulletin) | full text | Energy regulation: glazing performance and glazing ratio counted in the envelope justification. |
Materials and documents to request
| Material | Standards | Supporting documents | Basis |
|---|---|---|---|
| Powder-coated aluminium profiles | NM 03.2.232 | Coating reference and colour on the order, coater's declaration of conformity with the standard. | Legal obligation |
| Glass units (basic, toughened, laminated) | NM EN 572-1, NM EN 12150-1, NM ISO 12543-2 / -3 | Glass composition on the order and marking on toughened and laminated panes, consistent with the location of each window. | Legal obligation |
| Locks and cylinders | NM EN 12209, NM EN 1303 | Product reference and standard on packaging or data sheet; keys counted and handed over at acceptance. | Legal obligation |
| Frame-to-wall sealant | NM ISO 11600 | Sealant class on the cartridge, compatible with aluminium and the wall finish. | Legal obligation |
Who does what
| Party | Role |
|---|---|
| Architect | Specifies opening types, performance classes, glazing and colours, draws sill and reveal details and approves samples. |
| Thermal engineer | Sets the glazing and frame performance needed for the RTCM justification. |
| Aluminium joinery contractor | Takes site dimensions, produces shop drawings, fabricates and installs, and supplies certificates for glass, coatings and locks. |
| Rendering contractor | Prepares openings that are square and level, and finishes reveals after the frames are fixed. |
| Client (owner) | Approves the sample window and colour, and checks that safety glass is used where people could fall or impact the glazing. |
Inspection milestones
- Architectural details and coordination of openings Good practice
Window schedule with performance classes, glazing types and sill details coordinated with structure and façade. - Samples and finishes approved Specification (CPS) requirement
Sample window, profile colour and hardware approved in writing before the order is placed. - Renders, screeds and joinery installed Specification (CPS) requirement
Frames plumb, fixed and sealed; drainage slots clear; glass marking checked; opening sashes operating smoothly.
Common non-conformities and follow-up
| Finding | Action |
|---|---|
| Ordinary float glass fitted where the drawings call for laminated safety glass. | Replace the pane before handover; the specified glass is the one that protects occupants at that position. |
| Water entering at the sill after rain. | Check drainage slots, sill slope and sealant; correct and test with a hose in the presence of the architect. |
| Coating scratched or colour inconsistent between frames. | Touch-up only if the architect accepts it; otherwise replace the affected profiles. |
| Frame fixed with foam alone, without mechanical fixings. | Remove sealant where needed and add the fixings specified by the manufacturer. |
Frequently asked questions
Which aluminium window standards are mandatory in Morocco?
NM 10.2.002 for windows, NM 03.2.232 for powder coatings, the glass standards (NM EN 572, NM EN 12150-1, NM ISO 12543, NM EN 356), NM ISO 11600 for sealants and NM EN 12209 for locks.
Are air and water tightness classes compulsory?
The classification standards (NM EN 12207 for air, NM EN 12210 for wind) are homologated. The CPS should state the classes required for the building's exposure.
Is thermally broken aluminium required?
Not as such. The RTCM sets envelope performance, and the thermal engineer decides whether the glazing must use thermally broken frames to meet it.
Where must safety glass be used?
Wherever there is a risk of impact or fall, such as low glazing, glazed doors and guarding. The architect marks those positions on the window schedule.
What should be handed over with the windows?
Glass and coating certificates, the lock documentation, keys, and care instructions for seals and drainage.
Sources, author and revisions
- Official Bulletin No. 6306 (RTCM, Decree No. 2-13-874) (accessed 26/10/2026)
- Law No. 24-09 on product and service safety (Ministry of Justice legal portal) (accessed 26/10/2026)
- Moroccan Standards Institute (IMANOR), standards catalogue (accessed 26/10/2026)
Written by Yassine AT-TARASSI, architect · under review · updated . Professional reading, separate from the text of the standard: each requirement is classed as a legal obligation, a specification (CPS) requirement or good practice.
Revision log
- — English page created from the standards catalogue and project milestones. To be reviewed by the architect and a joinery specialist.
All standards for this trade (105)
In short: for the "Aluminium exterior joinery" trade, the library lists 4 Moroccan regulation(s), 14 mandatory Moroccan standard(s), 23 approved NM and 26 foreign reference(s) used as equivalents.
Moroccan regulations (4)
- Décret n° 2-13-874 du 15/10/2014, BO 6306 du 06/11/2014 — Règlement général de construction fixant les règles de performance énergétique des constructions (RTCM) mandatory PDF · full text
Exigences thermiques de l'enveloppe par zone climatique (6 zones), approche prescriptive ou performancielle ; texte intégral dans le BO 6306 FR. - Guides RTCM (version simplifiée, guide technique) et logiciel Binayate — Guides d'application du RTCM voluntary
Plus en ligne sur le nouveau site amee.ma (aucun PDF RTCM dans la médiathèque) ; à demander à l'AMEE. - Loi n° 24-09 (dahir 1-11-140 du 17/08/2011) — Sécurité des produits et des services mandatory PDF · full text
Obligation générale de sécurité des produits ; base des règlements techniques et du marquage CMIM. - Loi n° 47-09 (dahir 1-11-161 du 29/09/2011) — Loi relative à l'efficacité énergétique mandatory PDF · full text
Base légale des performances énergétiques des bâtiments (RTCM), des audits et des étiquettes énergie.
Mandatory Moroccan standards (NM) (14)
- NM 03.2.232 — Peintures thermodurcissables en poudre Exigences et méthodes d’essais mandatory
Norme marocaine d'application obligatoire (décision/arrêté d'homologation n° 2296-20) ; texte payant (référence seulement).
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM 10.2.002 — Fenêtres en bois ou en métal — spécifications mandatory
Ancienne norme fenêtres, toujours obligatoire.
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM 10.2.217 — Quincaillerie de bâtiment- Serrures à mortaiser verticales dites de 150, simples, de sureté à gorges ou de sureté à cylindres. mandatory
Norme marocaine d'application obligatoire (décision/arrêté d'homologation n° 7003-20) ; texte payant (référence seulement).
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM 10.7.028 — Verre arme plan pour vitrage de bâtiment mandatory
Norme marocaine d'application obligatoire ; titre relevé au catalogue IMANOR, texte payant (référence seulement).
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM 10.7.076 — Verre dans la construction Produits de base speciaux Vitroceramiques mandatory
Norme marocaine d'application obligatoire ; titre relevé au catalogue IMANOR, texte payant (référence seulement).
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM EN 356 — Vitrage de sécurité — résistance à l'attaque manuelle mandatory
Classes anti-effraction des vitrages ; obligatoire.
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM EN 572-1, -3, -6, -7 — Verre dans la construction — verre de silicate sodo-calcique mandatory
Produits verriers de base ; obligatoires.
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM EN 1303 — Quincaillerie pour le bâtiment- Cylindres de serrures- Exigences et méthodes d’essai mandatory
Norme marocaine d'application obligatoire (décision/arrêté d'homologation n° 3007-20) ; texte payant (référence seulement).
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM EN 1670 — Quincaillerie de bâtiment- Résistance à la corrosion- Exigences et méthodes d’essai mandatory
Norme marocaine d'application obligatoire (décision/arrêté d'homologation n° 3007-20) ; texte payant (référence seulement).
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM EN 12150-1 — Verre de sécurité trempé thermiquement mandatory
Verre trempé ; obligatoire.
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM EN 12209 — Quincaillerie pour le bâtiment -Serrures-Serrures mécaniques et gâches-exigences et méthodes d’essai mandatory
Norme marocaine d'application obligatoire (décision/arrêté d'homologation n° 692-11, entrée en vigueur le 18/03/2026) ; texte payant (référence seulement).
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM ISO 9051 — Verre dans la construction - Ensembles vitrés comportant du verre transparent ou translucide, résistant au feu, pour utilisation dans le bâtiment -04p. (IC 10.7.024) mandatory
Norme marocaine d'application obligatoire (décision/arrêté d'homologation n° 884-01) ; texte payant (référence seulement).
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM ISO 11600 — Produits pour joints Classification et exigences pour les mastics ; (IC 10.8.748) mandatory
Norme marocaine d'application obligatoire (décision/arrêté d'homologation n° 3946-18, entrée en vigueur le 15/08/2025) ; texte payant (référence seulement).
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR. - NM ISO 12543-2 / -3 — Verre feuilleté et verre feuilleté de sécurité mandatory
Verre feuilleté (garde-corps, vitrages bas) ; obligatoire.
Paid standard: the text is not reproduced; it can be consulted or purchased from IMANOR.
Approved Moroccan standards (NM, voluntary) (23)
- NM 01.4.030 — Emballages Emballages pour certains produits alimentaires preemballes capacites des recipients en verre et métalliques approved
- NM 10.2.208 — Menuiserie métallique Fenêtres, façades rideaux, semi rideaux, panneaux a ossature métallique protection contre la corrosion et preservation des etats de surface approved
- NM 10.2.483 — Travaux de bâtiment mise en œuvre des fenêtres et portes extérieures Cahier des clauses techniques types approved
- NM 10.2.488 — Travaux de bâtiment mise en œuvre des fenêtres et portes extérieures Partie 1 1 : Cahier des clauses techniques types approved
- NM 10.2.489 — Travaux de bâtiment mise en œuvre des fenêtres et portes extérieures Partie 1 2 : Critères généraux de choix des matériaux (CGCM) approved
- NM 10.2.490 — Travaux de bâtiment mise en œuvre des fenêtres et portes extérieures Partie 2 : Cahier des clauses administratives speciales types approved
- NM 10.8.004 — Profiles à base de caoutchouc pour fenêtres et éléments de façade Spécifications des matériaux de base approved
- NM EN 410 — Verre dans la construction Détermination des caractéristiques lumineuses et solaires des Vitrages approved
- NM EN 949 — Fenêtres et façades rideaux, portes, stores et fermetures Détermination de la résistance au choc de corps mou et lourd pour les portes approved
- NM EN 1026 — Fenêtres et portes — perméabilité à l'air — méthode d'essai approved
- NM EN 1027 — Fenêtres et portes — étanchéité à l'eau — méthode d'essai approved
- NM EN 1170-2 — Produits préfabriqués en béton Méthode d'essai des composites ciment verre Partie 2 : Mesure de la teneur en fibres du CCV frais, méthode dite �Separation par lavage approved
- NM EN 1170-3 — Produits préfabriqués en béton Méthode d'essai des composites ciment verre Partie 3 : Mesure de la teneur en fibres des CCV realises par projection approved
- NM EN 1279-1 — Verre dans la construction Vitrage isolant préfabriqué et scelle Partie 1 : generalites, tolerances dimensionnelles et règles de description du système approved
- NM EN 1706 — Aluminium et alliages d'aluminium Pieces moulees Composition chimique et propriétés mécaniques approved
- NM EN 12207 — Fenêtres et portes — perméabilité à l'air — classification approved
- NM EN 12210 — Fenêtres et portes — résistance au vent — classification approved
- NM EN 12211 — Fenêtres et portes — résistance au vent — méthode d'essai approved
- NM EN 13363-1+A1 — Dispositifs de protection solaire combines a des vitrages Calcul du facteur de transmission solaire et lumineuse Partie 1 : méthode simplifie approved
- NM EN 13363-2 — Dispositifs de protection solaire combines a des vitrages Calcul du facteur de transmission solaire et lumineuse Partie 2 : méthode de calcul detaillee approved
- NM EN 14220 — Bois et matériaux à base de bois dans les fenêtres extérieures, les vantaux de portes extérieures et les dormants de portes extérieures Exigences et spécifications approved
- NM IEC/TS 60815 2 — Selection et dimentionnement des isolateurs haute tension destines a etre utilises dans des conditions polluees Partie 2 : Isolateurs en céramique et en verre pour a.c. systèmes approved
- NM ISO 6946 — Résistance thermique et coefficient de transmission thermique — calcul approved
Eurocodes (7)
- EN 1999-1-1 à 1-5 — Eurocodes 2e génération — Aluminium — 2e génération draft
- EN 1999-1-1:2007 — Eurocode 9 — Aluminium — règles générales voluntary
- EN 1999-1-2:2007 — Eurocode 9 — Aluminium — calcul au feu voluntary
- EN 1999-1-3:2007 — Eurocode 9 — Aluminium — structures sensibles à la fatigue voluntary
- EN 1999-1-4:2007 — Eurocode 9 — Aluminium — tôles de structure formées à froid voluntary
- EN 1999-1-5:2007 — Eurocode 9 — Aluminium — coques voluntary
- EN 19100-1/-2/-3 (verre structurel) et CEN/TS 19101 (polymères renforcés de fibres), CEN/TS 19102 (membranes) — Eurocodes 2e génération — Nouveaux matériaux : verre structurel, composites, membranes draft
European and French standards (EN, NF, DTU) (10)
- Arrêté du 24/03/1982 modifié — Aération des logements mandatory
- Arrêté du 30/06/1999 — Caractéristiques acoustiques des bâtiments d'habitation mandatory
- Arrêtés des 13/06/2008 (global) et 03/05/2007 modifié (élément par élément) — Réglementation thermique des bâtiments existants mandatory
- Décret n° 2021-1004 du 29/07/2021 — Exigences de performance énergétique et environnementale des constructions de bâtiments (RE2020) mandatory
- EN 12208 — Fenêtres et portes — étanchéité à l'eau — classification voluntary
- EN 14351-1+A2 — Fenêtres et portes — norme de produit, caractéristiques de performance voluntary
- NF DTU 33.1 — Façades rideaux voluntary
- NF DTU 36.5 — Mise en œuvre des fenêtres et portes extérieures voluntary
- NF DTU 39 — Travaux de vitrerie-miroiterie voluntary
- NF DTU 44.1 — Étanchéité des joints de façade par mise en œuvre de mastics voluntary
Other jurisdictions (equivalents) (9)
- Approved Document F, volume 1 — Ventilation — Dwellings mandatory PDF · full text
- Approved Document K — Protection from falling, collision and impact mandatory PDF · full text
- Approved Document L, volume 1 — Conservation of fuel and power — Dwellings mandatory PDF · full text
- Approved Document L, volume 2 — Conservation of fuel and power — Buildings other than dwellings mandatory PDF · full text
- Approved Document O — Overheating mandatory PDF · full text
- Approved Document Q — Security — Dwellings mandatory PDF · full text
- CNÉB 2020 — Code national de l'énergie pour les bâtiments — Canada 2020 voluntary
- IECC 2024 — International Energy Conservation Code voluntary
- NAFS (AAMA/WDMA/CSA 101/I.S.2/A440) et supplément canadien CSA A440S1 — Norme nord-américaine sur les fenêtres voluntary
Cross-cutting texts (all trades) (38)
- Arrêté conjoint n° 337-20 du 21/01/2020 (BO 6874), modifié par l'arrêté 1032-21 (BO 6992) — Liste des documents et pièces du dossier de demande d'autorisation mandatory PDF · full text
- Arrêté conjoint n° 338-20 du 21/01/2020 (BO 6874) — Dématérialisation des procédures d'autorisation (plateforme Rokhas) mandatory PDF · full text
- Arrêté conjoint n° 1839-23 du 10/07/2023 (BO 7212) — Délais de chaque intervenant pour certaines décisions d'urbanisme délivrées par les communes mandatory PDF · full text
- Arrêté n° 3201-24 du 20/12/2024 (BO 7365) — Assurances construction (TRC et RC décennale obligatoires) mandatory PDF · full text
- BO n° 4225 du 20/10/1993 (édition FR) — Numéro complet du Bulletin officiel mandatory PDF · full text
- BO n° 6874 du 16/04/2020 (édition FR) — Numéro complet du Bulletin officiel mandatory PDF · full text
- Catalogue des normes marocaines — Catalogue NM (liste bibliographique avec indices et prix) voluntary
- Décret n° 2-12-349 du 20/03/2013 — Marchés publics (ancien décret) repealed or replaced
- Décret n° 2-13-424 du 24/05/2013 — Ancien règlement général de construction (autorisations) repealed or replaced PDF · full text
- Décret n° 2-14-394 du 13/05/2016 — Cahier des clauses administratives générales applicables aux marchés de travaux (CCAG-T) mandatory PDF · full text
- Décret n° 2-17-586 (application de la loi 94-12) — Décret d'application de la loi 94-12 (zones de rénovation urbaine) mandatory
- Décret n° 2-18-475 du 12/06/2019 modifié par le décret 2-23-103 du 08/05/2023 — Permis de réfection, de régularisation et de démolition mandatory PDF · full text
- Décret n° 2-18-577 du 12/06/2019, BO 6874 du 16/04/2020 — Règlement général de construction fixant la forme et les conditions de délivrance des autorisations et pièces exigibles mandatory PDF · full text
- Décret n° 2-22-431 du 15 chaabane 1444 (08/03/2023) relatif aux marchés publics, BO n° 7176 du 09/03/2023, p. 2861 ; en vigueur le 01/09/2023 (art. 169) — Marchés publics mandatory
- Décret n° 2-22-867 du 25/01/2023 — Règlement général de construction et commission nationale des normes de construction des établissements d'hébergement touristique mandatory PDF · full text
- Décret n° 2-23-103 du 08/05/2023 (BO 7194, AR) — Permis de régularisation des constructions non réglementaires (modifie le décret 2-18-475) mandatory PDF · full text
- Décret n° 2-92-832 du 14/10/1993, BO 4225 — Décret pris pour l'application de la loi 12-90 relative à l'urbanisme mandatory PDF · full text
- Décret n° 2-93-66 du 01/10/1993 — Décret pris pour l'application de la loi 016-89 (architectes) mandatory PDF · full text
- Documents d'urbanisme de Rabat-Salé — Plans d'aménagement de Rabat-Salé mandatory
- Guide des procédures relatives aux autorisations d'urbanisme — Guide des procédures relatives aux autorisations d'urbanisme (édition 2025, FR) voluntary PDF · full text
- Liste des réglementations techniques et normes d'application obligatoire — Liste des NM d'application obligatoire (mise à jour 15/04/2022) repealed or replaced PDF · full text
- Liste des réglementations techniques et normes d'application obligatoire — Liste des NM d'application obligatoire et des règlements techniques (mise à jour du 09/03/2026) voluntary PDF · full text
- Loi n° 12-03 (dahir 1-03-60 du 12/05/2003) — Études d'impact sur l'environnement (ancienne loi) repealed or replaced
- Loi n° 12-90 (dahir 1-92-31 du 17/06/1992), BO 4159 — Loi relative à l'urbanisme mandatory PDF · full text
- Loi n° 016-89 (dahir 1-92-122 du 10/09/1993), BO 4225 — Exercice de la profession d'architecte et institution de l'Ordre national des architectes mandatory PDF · full text
- Loi n° 18-00 modifiée par la loi 106-12 — Statut de la copropriété des immeubles bâtis mandatory PDF · full text
- Loi n° 22-80 (dahir 1-80-341 du 25/12/1980), BO du 18/02/1981 — Conservation des monuments historiques et des sites, des inscriptions, des objets d'art et d'antiquité mandatory PDF · full text
- Loi n° 25-90 (dahir 1-92-7 du 17/06/1992), modifiée par 66-12 — Lotissements, groupes d'habitations et morcellements mandatory PDF · full text
- Loi n° 49-17 (dahir 1-20-78 du 08/08/2020), BO 7140 du 03/11/2022 — Évaluation environnementale mandatory PDF · full text
- Loi n° 64-23 portant création des agences régionales d'urbanisme et d'habitat — Communiqué d'adoption de la loi 64-23 mandatory PDF · full text
- Loi n° 66-12 (dahir 1-16-124 du 25/08/2016), BO 6501 — Contrôle et répression des infractions en matière d'urbanisme et de construction mandatory PDF · full text
- Loi n° 81-12 (dahir 1-15-87 du 16/07/2015) — Loi relative au littoral mandatory PDF · full text
- Loi n° 94-12 (dahir 1-16-48 du 27/04/2016), BO 6466 du 19/05/2016 (FR) — Bâtiments menaçant ruine et organisation des opérations de rénovation urbaine mandatory PDF · full text
- Loi n° 107-12 modifiant et complétant la loi n° 44-00 relative à la vente d'immeubles en l'état futur d'achèvement (art. 618-1 et s. du DOC), dahir n° 1-16-05 du 03/02/2016, BO n° 6440 du 18/02/2016, p. 932 — Vente d'immeubles en l'état futur d'achèvement (VEFA) mandatory
- Loi-cadre n° 99-12 (dahir 1-14-09 du 06/03/2014) — Charte nationale de l'environnement et du développement durable mandatory
- Planification urbaine AUKSS — Plans d'aménagement du ressort de Kénitra mandatory
- Plans d'aménagement de Casablanca (par arrondissement) — état d'avancement — Plans d'aménagement de Casablanca mandatory
- Plans d'aménagement et règlements d'aménagement (par commune), loi 12-90 art. 18 s. — Plan d'aménagement et règlement d'aménagement de la commune du projet mandatory
2026 reference prices — Aluminium exterior joinery
Public reference prices from the CITURBAREA materials library (October 2026), in dirhams excluding VAT; 20% VAT on top (incl. VAT = excl. VAT × 1.2), Rabat-Salé-Kénitra base. These are benchmarks, not supplier prices.
| Material | From (excl. VAT) | From (incl. VAT) | Range excl. VAT | Reliability |
|---|---|---|---|---|
| Profilé aluminium | 29,16 DH / ml | 34,99 DH / ml | 29,16 DH – 70,42 DH | C (indicative) |
| Double vitrage 6/8/6 argon sans cadre (100 × 100 cm) | 208 DH / m² | 250 DH / m² | 208 DH – 209 DH | C (indicative) |
| Vitrage accordéon Kupa Glazing, verre trempé 10 mm (sur mesure) | 1 583 DH / m² | 1 900 DH / m² | 1 583 DH – 1 584 DH | C (indicative) |
| Vitrage accordéon Steelon, verre trempé 10 mm (sur mesure) | 1 250 DH / m² | 1 500 DH / m² | 1 250 DH – 1 250 DH | C (indicative) |
Detail in the estimator → · Reference prices and data sheets →
4 materials for this trade in the materials library. Menuiserie aluminium & PVC
Guides for this trade
See products, data sheets and supplier prices
Detailed offers by supplier, technical data sheets and product comparison are reserved for account holders. The account is free; no contact details are exchanged, everything goes through CITURBAREA.
Library maintained by CITURBAREA, construction and architecture platform in Morocco · tools for architects.
All trades
Site set-up · Earthworks · Foundations · Retaining walls & basement · Reinforced-concrete frame · Masonry · Waterproofing · Thermal insulation · Renders & screeds · Façades · Interior wood joinery · Metalwork, railings · Suspended ceilings, plaster · Floor finishes · Wall finishes (tiles, zellige) · Painting · Plumbing & hot water · Sanitary fixtures · Electrical (power & low current) · HVAC · Lift · Fire safety · Solar thermal & PV · Site works & landscaping · Swimming pool
Does your project comply with these texts?
A registered architect checks your project's compliance, from building permit to handover. Free overall estimate, first call with no commitment.
Estimate my project → Book a free video call Create my free account
Stay informed
Material prices, new planning rules and site advice: one letter a month, written by an architect.
▶ Subscribe to the YouTube channel Channel of architect Yassine AT-TARASSI: sites, prices and procedures on video.
Create my free account →
General information based on official texts: it does not replace a review of your own file. — Yassine AT-TARASSI, architect · Arc Bati Architecture